Editing Crushing ceiling linedef types

From Eternity Wiki
Jump to navigationJump to search
Warning: You are not logged in. Your IP address will be publicly visible if you make any edits. If you log in or create an account, your edits will be attributed to your username, along with other benefits.

The edit can be undone. Please check the comparison below to verify that this is what you want to do, and then publish the changes below to finish undoing the edit.

Latest revision Your text
Line 2: Line 2:


Once a crusher ceiling is started it remains running for the remainder of the level even if temporarily suspended with a stop type. No other ceiling action can be used in that sector thereafter.
Once a crusher ceiling is started it remains running for the remainder of the level even if temporarily suspended with a stop type. No other ceiling action can be used in that sector thereafter.
{{backto|Linedef types}}
 
=Varieties of Crushers=
=Varieties of Crushers=


Line 17: Line 17:
  Regular and Extended Crusher Types
  Regular and Extended Crusher Types
  -------------------------------------------------------------------
  -------------------------------------------------------------------
  #    Class  Trig  Spd  Mon Silent Action
  #    Class  Trig  Spd  Mon Silent Action ExtraData mnemonic
   
   
  184  Ext    SR    Slow No  No    Start
  184  Ext    SR    Slow No  No    Start   SR_StartCrusher_Slow
  49    Reg    S1    Slow No  No    Start
  49    Reg    S1    Slow No  No    Start   S1_StartCrusher_Slow
  73    Reg    WR    Slow No  No    Start
  73    Reg    WR    Slow No  No    Start   WR_StartCrusher_Slow
  25    Reg    W1    Slow No  No    Start
  25    Reg    W1    Slow No  No    Start   W1_StartCrusher_Slow
   
   
  183  Ext    SR    Fast No  No    Start
  183  Ext    SR    Fast No  No    Start   SR_StartCrusher_Fast
  164  Ext    S1    Fast No  No    Start
  164  Ext    S1    Fast No  No    Start   S1_StartCrusher_Fast
  77    Reg    WR    Fast No  No    Start
  77    Reg    WR    Fast No  No    Start   WR_StartCrusher_Fast
  6    Reg    W1    Fast No  No    Start
  6    Reg    W1    Fast No  No    Start   W1_StartCrusher_Fast
   
   
  185  Ext    SR    Slow No  Yes    Start
  185  Ext    SR    Slow No  Yes    Start   SR_StartCrusher_Silent_Slow
  165  Ext    S1    Slow No  Yes    Start
  165  Ext    S1    Slow No  Yes    Start   S1_StartCrusher_Silent_Slow
  150  Ext    WR    Slow No  Yes    Start
  150  Ext    WR    Slow No  Yes    Start   WR_StartCrusher_Silent_Slow
  141  Reg    W1    Slow No  Yes    Start
  141  Reg    W1    Slow No  Yes    Start   W1_StartCrusher_Silent_Slow
   
   
  188  Ext    SR    ---- --  --    Stop
  188  Ext    SR    ---- --  --    Stop   SR_StopCrusher
  168  Ext    S1    ---- --  --    Stop
  168  Ext    S1    ---- --  --    Stop   S1_StopCrusher
  74    Reg    WR    ---- --  --    Stop
  74    Reg    WR    ---- --  --    Stop   WR_StopCrusher
  57    Reg    W1    ---- --  --    Stop
  57    Reg    W1    ---- --  --    Stop   W1_StopCrusher
   
   
  Generalized Crusher Types
  Generalized Crusher Types
Line 48: Line 48:
                 G1/GR  Turbo
                 G1/GR  Turbo


[[category:Editing reference]]
''Back to [[Linedef types]]''
Please note that all contributions to Eternity Wiki are considered to be released under the GNU Free Documentation License 1.2 (see Eternity Wiki:Copyrights for details). If you do not want your writing to be edited mercilessly and redistributed at will, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource. Do not submit copyrighted work without permission!
Cancel Editing help (opens in new window)

Template used on this page: